First experience as an insulin pump user – and with the built-in AI (artificial intelligence)

After 23 years using an insulin pen, l finally made the big step (for me) starting to use an insulin pump. It is the most advanced pump available in Norway, the Medtronic 670G – so called “hybrid closed-loop insulin pump”. I thought this was a good opportunity to enter my thoughts and experiences as a new user to this here in my blog, while I still am new to using a pump. And also to get first-hand experience with AI and cyber-physical systems on my own body – it’s namely also part of my research at UiT and NSE.

If I get new information to the points below, or answers to my questions, I will add them subsequently.

  1. It’s a LOT of units and garbage: many elements, much battery-charging/changing, manual insulin administration, tube-, and reservoir replacements,  and much garbage generated during installation, and use!
    20200203_23454765111768656733929.jpg
  2. The user manuals are many, and many pages to read! I wonder if anyone reads them all, or if the manufacturer really think we should? We (6 participants) was given a rather thorough 5-hours introduction course given by the hospital and a representative from the manufacturer, but must admit that this just answered the very basic of my questions to this advanced system.
  3. The first days with the pump, I struggle to wear it, it always is in my way – I end up getting really irritated on the technology that is so present. I try different holders for the pump, most for attaching to the belt, but all of them gets in my way. Visiting the toilet becomes a “detailed-planned-expedition” for me. And sleeping with it – so bothersome. Hope I get used to it, and find good solutions.
  4. One of the main reasons I choose to try this pump is to get an easier life when hiking outdoors – where I often get many hypos. My first hike with the pump was a miserable one, I get hypo, plus I am not able to check my glucose since the pump is buried under layers of clothes, and it is snowing heavy – hindering me to open up the clothes checking the glucose. I was saved by my old Dexcom G4 sensor with the DIY Nightscout and xDrip app, sending glucose values to my Fitbit watch – so much easier! I wonder what to do when I run out of sensors to this device. Perhaps the DIY-community also have a smartwatch-solution for the Medtronic CGM?
    Answer: Yes there is a solution, but this is a very cumbersome one – needing to attach the Contour Next Link gllucose meter to my phone with a cable. You can read more here: Link
  5. After 48 hours running in “Manual mode” I was ready to enter the “Auto mode” – which is sad to use AI – exiting! BUT when in “Auto mode” –  how do I add a correction bolus when I have a glucose on 14 mmol/L. When trying to enter bolus by stating this high glucose, I was not allowed, given the message: “No bolus amount estimated. Canceling Bolus”. I had to leave the “Auto mode”, and enter the “Manual mode” – to be able to enter a correction bolus. Then I had to measure a glucose to calibrate the pump to go back into the “Auto mode” again.
  6. A solution to the problem adding correction bolus, may be to fool the pump by telling the pump that I am eating carbohydrates, even though I am not. But what consequences will this get for the AI algorithms that is supposed to be the strength of this pump – learning wrong information how I react on carbs. I do not want to fool the pump like this if it means that I will “teach” the pump wrongly about my physiology, giving me a sub-optimal solution.
  7. The pump is trying to kill me! At least if I follow its feedback to me blindly. So, it did not allow me to enter insulin when my glucose was 14, but when I the next day got a hypo with “Below 2.2 mmol/L” – it recommended me to inject 2 units of insulin after I added the carbs to correct the hypo!!
    Explanation:
    Even though the pump display the value of 2.2 mmol/L – it is expected that you measure and enter the glucose in the same screen where you enter the carbohydrates (I thought the pump was smart enough to use the low glucose value it already had from its CGM sensor). The only “safety function” of the pump to hinder this situation is a message saying that you should not inject any insulin when lower than 3.2 mmol/L, BUT after having OK’ed this message, you are still presented to the screen where you could OK the suggested insulin injection, in my case 2 units of insulin, with a glucose of 2.2 mmol/L!
  8. Right after I had my carbs to bring up the glucose from 2.2 mmol/L, (I had to fool the pump again – i.e. not tell about my carb intake – to not kill myself with more insulin), the sensor needed calibration. It asked for two calibrations, and after the second it asked for, the pump said I needed to change the sensor – after only 4 days!! (My dexcom G4 lasted up to 4 weeks). I did, after first having to charge the transmitter, which is also an extra hassle and time tap compared with other CGMs. I have had (Dexcom and Freestyle sensors earlier). It is now warming up, meaning it will wake me up during the night, asking for calibration. Really hope it accept those ones.
    Explanation: After 1 month i had a consultation with my very skilled diabetes nurse, who gave me this advice for how to avoid this sensor problem: Only enter measured glucose values that are less than 35% different than the CGM value, even if it is larger. If if is more than 35% different, then enter glucose and calibrate the pump more times, entering a wrong value, but closer to the real value. (The reason is that else the pump think the sensor is damaged or wrong, and need replacement – since it deviates so much from the real value).
  9. It did accept the new calibration glucose (at 01:00 in the night), but it waked me up again at 03:00 in the night asking for another calibration. I guess you can imagine this is annoying.
    Explanation: After 1 month of use, I have learned that I need to check before bedtime if calibration is needed during the night, and if so, do a calibration right before bedtime, that extend the time until next calibration. But even if I do so, I am waked up several nights during the week with other alarms, that I do not yet see how to avoid. My skilled nurse confirms this, that some of these is hard to avoid.
  10. The glue on the Medtronic CGM sensor makes my skin very red and irritated , even just after the 4 days I wore it – so I obviously need some skin cream or other aids for that – any tips anyone? The Dexcom 4G sensor could be on up to 4 weeks, with less irritation/red skin than this sensor.
  11. One week after startup on the pump, me and 3 others were gathered at the hospital for a follow-up course. This was very useful, and I got clarified the issue I was especially concerned about – see point 7 above –  where I have explained this in point 7 under “Explanation”. Worth to mention is that 50% of us had misunderstood what is needed to add carbohydrates to the pump.
  12. The second time I changed sensor, my skin did NOT react negatively on the glue, as it did the first time (see point 10). Does the skin adapt to the chemicals in the glue?
  13. Stay tuned – more experiences will come, mostly as “Explanations” or “Answers” to the points above.

 

We need Bluetooth Insulin pens now!

I met Arnaud Guillet  from BioCorp at the recent #ATTD2018 conference in Vienna, and his company seems to have a promising system. Look forward to testing!

BioCorp-InsulinPen

Student – Join our research team!

Many students have worked with us in mHealth research – here is what Pietro Randine from Università degli Studi di Milano Bicocca developed for his bachelor thesis this spring!

If you are interested in visiting us, feel free to send us an e-mail at diabetesdagboka@telemed.no

 

How data can be transferred from the FreeStyle Libre to a diabetes diary app

See the video at YouTube for an example on how data can be transferred from the FreeStyle Libre to a diabetes diary app.

Illustrasjonsbilde-Freestyle-Libre-into-DD

So easy to attach the FreeStyle Libre

This sensor is so much easier to use attach than the CGMs on the market, and needs no calibration. Of course, you get no alarms, so the usage is different, and one have to consider what is needed in each case. See video on: YouTube.

AttachFreestyleLibre

Our Diabetes research portfolio presented at Nordic mHealth Congress

Diabetes Diary at Nordic Mhealth Conference.

FI-STAR attends Norwegian Health Conference

FI-STAR attends Norwegian Health Conference.

Diabetes app for the Pebble smartwatch

Now the Diabetes Diary it is available from Pebble’s app store – just install the Pebble app on your phone, and search for “diabetes” to find the app. The Diabetes Diary Pebble app works both stand-alone (world-wide) and together with the Android app with the same name (currently Norway only). It allows the user to view and enter registrations – including automatic step counts – into the watch and Android phone app, and reminds you to measure blood glucose. It also displays time/date and is intended to be used as the user’s regular watch. We are curious to hear your experience with it!

The Pebble app was made in cooperation between Faculty of Biomedical Engineering, Czech technical University in Prague – FBME CTU, and Norwegian Centre for Integrated Care and Telemedicine (NST), University Hospital of North Norway.

Create your own website, free on WordPress.com.Create your own website.
Start free